AICPS Review - 2 / 2006
1. SOLUTIE CONSTRUCTIVA UTILIZATA PENTRU REALIZAREA COMPLEXULUI COMERCIAL “DRAGONUL ROSU” – SITUAT IN COMUNA DOBROESTI – SECTOR AGRICOL ILFOV
STRUCTURAL SOLUTION APPLIED TO THE CONSTRUCTION OF THE SHOPING CENTER “DRAGONUL ROSU”, DOBROESTI TOWN, ILFOV
Dr. Ing. Helmut Köber, Ing. Nicolae Dutoiu, Ing. Stela Neculcea
1
2. PROIECTUL STRUCTURII COMPLEXULUI COMERCIAL CORA, LUJERULUI
STRUCTURAL DESIGN OF THE SHOPPING CENTER “CORA” –
LUJERULUI, BUCHAREST
Prof.dr.ing. Zoltan Kiss Ing. Petre Dragomir
6
3. STRUCTURA METALICA A CRUCII MONUMENTULUI DE LA
MUNTELE MIC
STEEL STRUCTURE OF THE CROSS OF THE MONUMENT ERECTED ON MUNTELE MIC (PART I)
Dr. ing. Radu-Victor Marinov, ing. Ioan Cionca
12
4. STRUCTURA METALICA A CRUCII MONUMENTULUI DE LA
MUNTELE MIC – (piese scrise)
STEEL STRUCTURE OF THE CROSS OF THE MONUMENT ERECTED ON MUNTELE MIC (PART II)
Dr. ing. Radu-Victor Marinov, ing. Ioan Cionca
23
5. CONSOLIDAREA CORPULUI B DIN COMPLEXUL ADMINISTRATIV NAVROM IN SOLUTIA SERB – SITON PRIN CONTROLUL, LIMITAREA SI AMORTIZAREA MISCARILOR SEISMICE
STRENGTHENING OF BUILDING B OF THE ADMINISTRATION COMPLEX NAVROM BY APPLYING “SERB – SITON” SOLUTION FOR CONTROLLING, LIMITING AND DAMPING SEISMIC MOVEMENTS.
Dr. ing. Viorel Serban; dr. ing. Marian Androne; ing. George Ciocan; ing. Madalina Sendrea
39
6. CODUL DE EVALUARE SEISMICA A CONSTRUCTIILOR EXISTENTE P100, PARTEA A 3-A.
CONCEPTE SI METODE
CODE FOR SEISMIC ASSESSMENT OF EXISTING BUILDINGS P100-PART 3: CONCEPTS AND METHODS
T. Postelnicu, D. Zamfirescu
58
7. ELEMENTE DE NOUTATE PRIVIND PROIECTAREA STRUCTURILOR DE BETON ARMAT ÎN PREVEDERILE P100-1/2003
NEW DEVELOPMENTS IN THE DESIGN OF REINFORCED CONCRETE STRUCTURES INTRODUCED IN THE CODE P100/1-2004
Prof.Dr.Ing.Tudor Postelnicu, Prof.Dr.Ing Radu Pascu
73
8. CONFORMAREA STRUCTURILOR METALICE LA ACTIUNI SEISMICE IN CONCEPTIA NORMATIVULUI P100-1/2004 COMPARATIV CU PREVEDERILE EXISTENTE ( P100-92)
CONCEPTS RELATED TO SEISMIC CONFIGURATION OF STEEL STRUCTURES: COMPARISON BETWEEN THE NEW (P100-2004) AND THE EXISTING (P100-92) CODE.
Prof.dr.ing. Serban Dima, Conf.dr.ing. Paul Ioan, Asist.dr.ing. Helmuth Kober, Asist.drd.ing. Dan Bitca
86
9. VERSIUNEA ÎN LIMBA ROMÂNA AEUROCOD 4 – PARTEA 1-1;
Proiectarea structurilor compozite otel si beton; Reguli generale si reguli pentru cladiri
ROMANIAN VERSION OF EUROCODE 4-PART 1-1: DESIGN OF COMPOSITE STEEL - CONCRETE STRUCTURES – GENERAL RULES AND RULES FOR BUILDINGS
Ing.Mircea MIRONESCU
102
10. P100-1/2004 PREVEDERI SPECIFICE PENTRU CONSTRUCTII DIN ZIDARIE
ALINIEREA LA PRINCIPIILE SI REGULILE DE PROIECTARE DIN EUROCODE 6
- Proiectarea structurilor din zidarie - si din Eurocode 8, Cap.9
- Reguli specifice pentru cladiri din zidarie-
SPECIFIC REGULATION FOR MASONRY BUILDINGS INCORPORATED IN THE CODE P100/1-2004. HARMONISATION WITH DESIGH RULES OF EUROCODE 6 AND EUROCODE 8 – CHAPTER 9
Prof.Dr.Ing.Radu Petrovici
105
11. P100-1/2004 PREVEDERI SPECIFICE PENTRU COMPONENTELE NESTRUCTURALE ALE CONSTRUCTIILOR
ALINIEREA LA PRINCIPIILE SI REGULILE DE PROIECTARE DIN FEMA 450/IBC2003 (USA) Asemanari si deosebiri fata de Eurocode 8
SPECIFIC REGULATION FOR BUILDING NON-STRUCTURAL COMPONENTS INCORPORATED IN THE CODE P100/1-2004. HARMONISATION WITH DESIGN PRINCIPLES AND RULES OF FEMA 450/IBC2003 (USA).
Prof.Dr.Ing.Radu Petrovici
113
12. PROBLEME SPECIFICE PROIECTARII UNEI CLADIRI ÎNALTE CU STRUCTURA METALICA IN CONFORMITATE CU PREVEDERILE P100/2004 SI COMPARATIE CU P100/1992 - PARTEA A I-A
SINTEZA COMPARATIVA A PREVEDERILOR DIN P100/2004 SI P100/1992 PENTRU STRUCTURI IN CADRE METALICE MULTIETAJATE
SPECIFIC PROBLEMS RELATED TO A HIGH-RISE BUILDING WITH STEEL STRUCTURE DESIGNED ACCORDANCE WITH THE CODE P100/1-2004 AND COMPARISON WITH THE CODE P100-92. PART 1: SYNTHESIS OF REGULATIONS INCORPORATED IN BOTH CODES FOR MULTISTORY STEEL FRAME STRUCTURES
Prof.Dr.Ing Dan Dubina, Dr.Ing.Florea Dinu, Aurel Stratan
127
13. PROBLEME SPECIFICE PROIECTARII UNEI CLADIRI ÎNALTE CU STRUCTURA METALICA IN CONFORMITATE CU PREVEDERILE P100/2004 SI COMPARATIE CU P100/1992 - PARTEA A II-A
STUDIU DE CAZ: CLADIREA BUCHAREST TOWER CENTER
SPECIFIC PROBLEMS RELATED TO A HIGH-RISE BUILDING WITH STEEL STRUCTURE DESIGNED IN ACCORDANCE WITH THE CODE P100/1-2004 AND COMPARISON WITH THE CODE P100-92. PART 2: CASE STUDY “BUCHAREST TOWER CENTER” BUILDING.
Prof.Dr.Ing.DanDubina, Dr.Ing.Florea Dinu, Dr.Ing.Aurel Stratan, Prof.Dr.Ing.Anatolie Marcu, Ing.Dragos Marcu, Ing.Madalin Coman
135
14. ASPECTE SPECIFICE CALCULULUI SI PROIECTARII STRUCTURILOR DIN OTEL SI MIXTE OTEL-BETON LA ACTIUNEA FOCULUI
ÎN CONTEXTUL PREVEDERILOR DIN NORMELE EUROCODE
SPECIFIC ASPECTS OF THE COMPUTATION AND DESIGN OF STEEL AND STEEL – CONCRETE COMPOSITE STRUCTURES SUBJECTED TO FIRE ACTION, IN THE CONTEXT OF EUROCODE REGULATIONS.
Dr. ing Raul Zaharia, Prof.Dr.Ing. Dan Dubina
148
15. POATE FI APLICAT IN ROMANIA EUROCODE 8: „DRAFT Nr. 6/2003“?
COULD THE EUROCODE 8 “DRAFT NO. 6/2003” BE APPLIED IN ROMANIA ?
Dr.Ing.Viorel Serban, Ing.Marian Androne, Ing.T. Sireteanu
161
16. ASIGURARI 2006
PROFESSIONAL INSURANCE 2006
179
NOTA:
• Articolele nr. 1-5 constituie prezentari ale unor lucrari propuse pentru premiile AICPS-2006
• Articolele nr. 6-15 constituie comunicari ce urmeaza a fi prezentate in cadrul Conferintei Nationale AICPS-2006
NOTE:
• The papers no. 1-5 are presentations of some design works nominated for AICPS Awards 2006
• The papers no. 6-15 are to be presented at the AICPS National Conference 2006